Certificate of inspection

Datos Generales
Name of Vessel
MINERVA ALICE
IMO Nr
9309435
Flag
MALTA
Class
LR
Date of Service
04/05/2024
Place of Service
SARROCH
Certificate Nr
002-24-0651
WE HEREBY CERTIFY THAT THE EQUIPMENT AS SPECIFIED BELOW HAS BEEN INSPECTED AND SERVICED AS PER FOLLOWING SERVICE REPORTS
Nr System / Equipment Service Type
1 BA COMPRESSOR AND AIR QUALITY TEST
2 BREATHING AIR APPARATUS Service report attached ✏️
3 BA CYLINDERS SPECIFICATION Service report attached ✏️
4 CO2 HIGH PRESSURE SYSTEM - CARGO VESSELS Service report attached ✏️
5 CYLINDERS SPECIFICATION Service report attached ✏️
6 ESCAPE SETS Service report attached ✏️
7 ESCAPE SETS CYLINDERS SPECIFICATION Service report attached ✏️
8 FIRE EXTINGUISHERS Service report attached ✏️
9 PORTABLE FOAM APPLICATOR Service report attached ✏️
10 FOAM SYSTEM - DECK Service report attached ✏️
11 IMMERSION SUITS Service report attached ✏️
12 PROTECTIVE SUITS Service report attached ✏️
13 INFLATABLE LIFE JACKETS Service report attached ✏️
14 MEDICAL OXYGEN SYSTEM Service report attached ✏️
15 MED. OXYGEN SYSTEM CYL. SPECIFICATION Service report attached ✏️
16 MEDICAL OXYGEN APPARATUS Service report attached ✏️
17 MED. OXYGEN APPARATUS CYL. SPECIFICATION Service report attached ✏️
18 LAFF & WATER BASED FI FI SYSTEM Service report attached ✏️
19 LIFEBOAT AIR CYLINDER SPECIFICATION Service report attached ✏️
Description of system / Technical information of air compressor unit
Maker
Type
Serial Nr 5106-1338-3
Filling pressure 200 & 300 BAR
Capacity (liter /min) 100
Year of manufacture 2007
Running hours -
Nr Description of inspections Status Comment
1 Compressor visually inspected, V–belts checked
✏️
2 Performed running test for mechanical correct functioning
✏️
3 Condensate drain checked
✏️
4 Lube oil replaced
✏️
5 Lube oil level checked
✏️
6 Inlet filter replaced
✏️
7 Inlet filter cleaned and re-installed
✏️
8 Final filter replaced
✏️
9 Final filter inspected and re-installed
✏️
10 Final safety valve(s) checked
✏️
11 Compressor capacity checked
✏️
12 Filling gauge(s) checked with verified gauge
✏️
13 Changeover device / valve checked
✏️
14 Filling hose(s) and connection checked
✏️
Inspections / tests are in accordance with MSC.1 / Circ.1432. Air quality requirements to EN 12021:2014 standard – Annual
Nr Air Quality Test w/tubes Results Comments
1 Air Quality check: CO < 5 ppm 0
2 Air Quality check: CO2 < 500 ppm 100
3 Air Quality check: H2O < 50mg/mm3 (40-200 bar) -
4 Air Quality check: H2O < 35 mg/m3 (>200 bar) -
5 Air Quality check H2O < 25 mg/m3 (measured from compressor) 25
6 Air Quality check: Oil < 0,5mg/m3 0
7 Air Quality check: O2 21 % vol ± 1% 21
8 Air Quality check: NO2 0.0 ppm -
9 Odor / Taste NO ODOUR
Clarifications
Done Performed
Not done Not done / Not carried out due to ship operations at time of service
N/A Not due on the present service
Not valid Indicated test not possible due to system/equipment design (e.g. not existing)